Sök:

Sökresultat:

73 Uppsatser om Well insulated roofs - Sida 1 av 5

Gröna tak som del i ett hållbart stadsbyggande

Green roofs have seen a revival in the society of today. They provide many functions of which both society as a whole and the individual can take part. In particular extensive green roofs, that requires little or even zero maintenance, provides very valuable functions. Green roofs affect our environment and our economy in a positive manner as well as the physical expression of buildings. In this bachelor thesis the impact of green roofs on society has been examined throughout literature studies. The result as a compilation of contemporary research in this field is presented together with a discussion about the use of green roofs in general. The two major arguments for an extended use of green roofs are, the high stormwater retention capacity and the cost-benefits seen over time compared to a conventional roof.

Isolerande balkonginfästningar : Thermally-insulated balconies

In this work a study has been performed to show the different kinds of insulated balcony connections exists on the market. In the work there is also a short description of thermal bridges concerning balconies. A description of older solutions for balcony connections is given as well as a calculation of the difference in energy costs for a insulated balcony connection compared to the standard connection. The work includes a short description of the different products. After that there is a short information about their insulation properties, durability, acoustic performance, assembly, computer programme and a short analyses for each product..

Analys av fuktomlagring i välisolerad parallelltak : Analys med simuleringsprogrammet Wufi 2D

Idag ökar man isoleringen alltmer i takkonstruktion för att spara energi. Ökad mängd isolering minskar temperaturen över takets yttre delar och höjer den relativa fuktigheten där.  Dessutom finns risk att fuktigt material byggs in mellan alltmer täta skikt vilket leder till att det tar längre tid för byggfukten att torka. Detta resulterar i en ogynnsam fuktfördelning med höga relativa fuktigheter över konstruktionen där risken för mikrobiell påväxt ökar. Syftet med denna studie är att utreda hur fuktomlagring sker baserad på inbyggnadsfuktkvoten i välisolerade parallelltak.

Standardisering av snöröjningsplan : Instruktioner, råd och tips för snöröjning av tak med stora spännvidder

The Swedish winters 2009/10 and 2010/11 were rich in snow and many roofs collapsed, mainly largespan frames. Investigations were made and the amount of snow was not the primary cause, insteadthere were several other causes. One of these was that in some cases roofs were shoveled in anunfavorable manner which affected the load patterns negatively, so causing the roofs to collapse.Most people lack the knowledge of how shoveling will affect the roof. Had there been an increasedunderstanding regarding shoveling, some roofs could have been prevented from collapsing.Through both qualitative and quantitative research in the form of interviews and calculations thetheoretically best ways to shovel a selection of roof types is presented in the report. The roofstructures covered are 3-compartment, continuous and Gerberspliced metal roof decks.

KONTROLLBERÄKNING AV ETT TAKRAS PÅ EN TENNISHALL I NYKÖPING : En jämförelse mellan Eurokod och BKR

?Boverket? the Design Regulations in Sweden, also called BKR has for a long timebeen the mandatory standard that has guided and regulated construction design. Butat the end of 2010 BKR was replaced with Eurocode. This report deals with thecomparison of these two standards when it comes to wood construction. Duringwinter 2009/2010 there were many roof collapses due to excessive loads on theroofs across Sweden.

Sticklingsetablering av Sedum spp. för gröna tak : biokol som organiskt material i substrat

The popularity of vegetated, or green roofs, has grown over the past years due to their potential function of maintaining urban environment quality. The aim of this study was to investigate if substrates with different organic material, peat and charcoal, with two contents (3 or 6 weight%) influenced the growth of the cuttings during the first critical period of the establishment. Biochar is used as amendment to agricultural soils and has, theoretically, many of the properties suitable as organic content in green roof-substrates. Peat is one of the materials that is commercially used in green roof industry. The substrate has been treated with different amounts of water.

Biodiversitet av evertebrater på vegetativa tak

In a city sometimes conflicts arise between either to save the species-rich vacant lots where many species thrive, or to build new buildings. Green roofs can then serve as a refuge for plants and animals that have had their natural habitat destroyed or diminished. Today we know too little about green roofs contribution to the biodiversity in the cities. We also know very little about how various types of vegetation on roof can increase biodiversity and its ability to attract different species.The aim with this study was to examine how different types of vegetation on the roofs affect the biodiversity of the invertebrate and how species-composition and number of individuals differ between the roof- and groundlevel.This study has been carried out on Augustenborg Botanical Roof Gardens in Malmo, and in an area about 1.5 kilometers away from Augustenborg. Three different types of vegetation on the roof and ground floor were selected: sedum- ruderal and grass.

Fuktomlagringar i välisolerade ytterväggar : En undersökning för att fastställa en rimlig inbyggnadsfuktkvoti träreglar med fuktsimuleringsprogrammet Wufi 2D

To save energy it?s popular to build houses with low energy loss. In these houses the walls are keeping a lower temperature in the external side which leads to a higher relative humidity. In addition more material, such as wood studs, are used which means that there is more moisture to dry. More moisture in combination with higher relative humidity may pose a higher risk of microbial growth.

Byggkostnader inom mjölkproduktionen - jämförelse av olika stallstorlekar och byggnadstekniska utföranden

Investment costs for eight different type housing systems for dairy cows has been calculated in order to compare the building costs as a function of herd size, shelter type and automatization. A commercial calculation programme for building was used and complemented with prices of equipments specific for dairy cow building. Herd sizes were 120, 250 and 400 cows. The milking equipments were automatic milking system (AMS), parallel parlour with 32 stalls (2x16) and rotary parlour with 24 stalls. Shelter was either insulated equipped with automatic cable driven scrapers on solid alleys, automatic feed wagon on rails, or uninsulated with manual manure handling and a tractor driven mobile mixer wagon on a drive-through feeding table. Building cost per cow or per kg milk was calculated using an average life time and 6 % interest rate and annual milk yield is 9 500 kg/cow and year. Structure effect 3-4 % higher for an insulated structure than in an uninsulated for 400 and 120 herd respectively. This is much lower compared to what is normally argued.

Biosolar Roofs ? gröna tak version 2.0 : en plats för biologisk mångfald, solpaneler och pollinatörer

Urbanisering och förtätning leder till att habitat fragmenteras och att grönytor minskar, vilket gör det svårt att värna om den biologiska mångfalden. Ett exempel på grön infrastruktur är gröna tak som blir ett självklart val för att sammanfoga grönytor i en stad. Förutom flera privat- och samhällsekonomiska vinster, kan gröna tak bidra till att öka den biologiska mångfalden. Vegeterade tak består vanligen av prefabricerade mattor som har ett tunt substratdjup med en vegetation som främst består av Sedum album och mossa. För den biologiska mångfalden har dessa mattor ett lågt värde till skillnad från biodiversitetstak som hyser en mer varierad flora och fauna.

Solel till Akademiska sjukhuset : möjlig genererad effekt och solcellers estetiska konsekvenser

Today many buildings and it´s nearby surroundings are designed to achieve some kind of environmental goal.The issue concerning energy consumption is currently at focus and it is relevant that we start increase the share of renewable energy. Solar energy is an infinite resource and should therefore be considered when selecting an energy supplier. Uppsala University hospital is facing major restructuring when parts of the existing buildings will be refurbished and a large new building will be constructed. White Architects have developed a study concerning the new building and for some of the existing buildings on the hospital campus. Uppsala County requires tough energy measures and wants the new building to be classified as an eco-building in Whites following work. The classifications will involve high energy source requirements. This work has been conducted to see if solar power can be envisaged as a supplementary energy source for the University hospital and also to investigate the aesthetic impact of solar cells on the new building.

Utvärdering av befintliga passivhus : En byggnadsfysikalisk bedömning och mätningar om temperatur, och fukt analys på ytterväggarna

Energy price are on the way up to a high level that will not diminish in the future make us to focus more on the sustainable development for a better solution of residential houses. Passive house or low energy housing are one of the solution to make residential more environment friendly, in same time it´s a financial security using less energy, and saving money. The last 10 years in Germany and all around Europe the concept of passive house been developed, and people aim to know more about these concept that leading the market more attractive for passive houses. A passive house is a well designed building highly insulated and air tight with mechanical ventilated system for the whole building envelope that minimizes the use of energy for heating [1].The housing company Mimer has chosen to invest in low energy consumption in every new housing project.  These future plan projects are decided to use less than 75 kwh per square meter annually in purchased energy [2].This thesis is about new constructed passive houses, and focuses on the evaluations of the temperature, and moisture condition for attic, external walls and joist.

Effektiv lagerstyrning genom tillförlitlig prognostisering : Effective inventory control through reliable forecasting

This study was done regarding whether sealing or ventilation is the best solution to prevent moisture on cold attics. The authors of this report addressed the problem with moisture in attics when they started their cooperation with Peab.The methods included interviews with people, database research, and calculations of a project in Akersberga north of Stockholm. The conclusion is based on interviews and other information as they are analyzed in relation to the house of reference. The focus of this report is on problems with moisture in the attics known as cold attics.The background of the problem with moisture is that today?s slabs are usually insulated to save energy and that the attics nearly gives the climate as the outdoor climate.

Tätning eller ventilering mot fukt på kalla vindsutrymmen

This study was done regarding whether sealing or ventilation is the best solution to prevent moisture on cold attics. The authors of this report addressed the problem with moisture in attics when they started their cooperation with Peab.The methods included interviews with people, database research, and calculations of a project in Akersberga north of Stockholm. The conclusion is based on interviews and other information as they are analyzed in relation to the house of reference. The focus of this report is on problems with moisture in the attics known as cold attics.The background of the problem with moisture is that today?s slabs are usually insulated to save energy and that the attics nearly gives the climate as the outdoor climate.

Social hållberhet genom medborgardialoger : exemplet Husby

Understensho?jden is Stockholm's largest eco-village which was built in the early 1990s with the vision of enabling ecological living for people. However the ecovillage is no longer considered as environmentally friendly because of its relatively high energy consumption, and non-updated energy system. The purpose of this study is therefore to investigate how Understensho?jden should reduce their energy consumption and upgrade its energy system by using Blower-Door, IR-camera and Design Builder.

1 Nästa sida ->